Time the gas hold.
Hand over the certificate.

GasTest Log runs the pressure test on your iPhone: the code preset sets the pressure and the hold, the timer runs on the wall clock, and the start and end gauge photos end up on a one-page PASS/FAIL certificate you can hand to the inspector before you leave.

Get it on the App Store Free pressure & hold calculator

3 psi
Base preset
3 psi · for 10 min
Test medium
Air · or nitrogen, CO₂
Proof on the certificate
2 photos · start and end gauge

Three taps on site

No paperwork afterwards. The report is finished when the hold is.

  1. Pick the presetResidential or your own values. The app shows which code section the default comes from, so you can check it against your inspector's expectations before you pump up.
  2. Photograph the gauge and start the holdThe timer runs on the wall clock, so it keeps counting with the screen off. Haptic checkpoints tell you where you are without looking.
  3. Export the certificateOne page: address, gas, medium, test pressure, hold time, both gauge photos, the code citation, and PASS or FAIL.

What it looks like

Hold timer counting down with the current pressure, hold and medium Gauge photo captured as proof of the start of the test New test screen with code presets and the AHJ warning One-page pressure test certificate ready to export

The numbers the app starts from

These are the base IFGC and IRC defaults the app ships with. They are a starting point, not a ruling: your local amendments win.

WhatDefault
Test pressure 3 psi1.5× the working pressure, and never below 3 psi — IFGC 2021 §406.4.1
Hold time 10 minOnly for a single-family dwelling or a system under 10 ft³. Bigger systems hold half an hour per 500 ft³ — IFGC 2021 §406.4.2 · IRC §G2417.4
Test medium Air, N₂, CO₂The code lists air, nitrogen, carbon dioxide or an inert gas, and forbids oxygen — IFGC 2021 §406.2 · IRC §G2417.2
Gauge ≤ 5× scaleA manometer, or a dial gauge whose top of scale is no more than 5× the test pressure — IFGC §406.4

Confirm with your AHJ. Jurisdictions amend these numbers, and some utilities ask for a higher pressure or a longer hold than the model code. The app says the same thing on the test screen — check first, then pump up.

Free tools, no app needed

Questions people ask

Does the timer keep running if I lock the phone?

Yes. The hold is measured against the wall clock, so locking the screen or leaving the app does not lose time.

Can I finish a test early?

Yes. If the gauge drops you can end the hold immediately and the certificate records a FAIL with the time it happened.

Is the certificate accepted by inspectors?

The certificate is your record of the test: pressure, hold, both gauge photos and the code section. Whether a jurisdiction accepts a photographed record instead of a witnessed test is up to that jurisdiction — ask your inspector before the appointment.

Does it work offline?

Yes, the test and the certificate are produced on the phone.